SubjectRe: [PATCH 08/13] net: ravb: Rely on PM domain to enable refclk
From
Date
On 11/20/23 11:46 AM, Claudiu wrote:

> From: Claudiu Beznea <claudiu.beznea.uj@bp.renesas.com>
>
> For RZ/G3S and RZ/G2L SoCs the Ethernet's reference clock is part of the
> Ethernet's power domain. It is controlled though CPG driver that is
> providing the support for power domain that Ethernet belongs. Thus,
> to be able to implement runtime PM (at least for RZ/G3S at the moment)
> w/o the need to add clock enable/disable specific calls in runtime PM
> ops of ravb driver and interfere with other IP specific implementations,
> add a new variable to struct_hw_info and enable the reference clock
> based on the value of this variable (the variable states if reference
> clock is part of the Ethernet's power domain).
>
> Signed-off-by: Claudiu Beznea <claudiu.beznea.uj@bp.renesas.com>

Reviewed-by: Sergey Shtylyov <s.shtylyov@omp.ru>

[...]

MBR, Sergey

\
 
 \ /