lkml.org 
[lkml]   [2021]   [Nov]   [7]   [last100]   RSS Feed
Views: [wrap][no wrap]   [headers]  [forward] 
 
Messages in this thread
Patch in this message
/
From
Subject[PATCH 1/4] bq25890_charger: Rename IILIM field to IINLIM
Date
Rename the Input Current Limit field in the REG00 from IILIM to IINLIM
accordingly with the bq2589x datasheet. This is just cosmetical change
to reduce confusion.

Signed-off-by: Yauhen Kharuzhy <jekhor@gmail.com>
---
drivers/power/supply/bq25890_charger.c | 12 ++++++------
1 file changed, 6 insertions(+), 6 deletions(-)

diff --git a/drivers/power/supply/bq25890_charger.c b/drivers/power/supply/bq25890_charger.c
index 34ec186a2e9a..34467bfb9537 100644
--- a/drivers/power/supply/bq25890_charger.c
+++ b/drivers/power/supply/bq25890_charger.c
@@ -40,7 +40,7 @@ static const char *const bq25890_chip_name[] = {
};

enum bq25890_fields {
- F_EN_HIZ, F_EN_ILIM, F_IILIM, /* Reg00 */
+ F_EN_HIZ, F_EN_ILIM, F_IINLIM, /* Reg00 */
F_BHOT, F_BCOLD, F_VINDPM_OFS, /* Reg01 */
F_CONV_START, F_CONV_RATE, F_BOOSTF, F_ICO_EN,
F_HVDCP_EN, F_MAXC_EN, F_FORCE_DPM, F_AUTO_DPDM_EN, /* Reg02 */
@@ -153,7 +153,7 @@ static const struct reg_field bq25890_reg_fields[] = {
/* REG00 */
[F_EN_HIZ] = REG_FIELD(0x00, 7, 7),
[F_EN_ILIM] = REG_FIELD(0x00, 6, 6),
- [F_IILIM] = REG_FIELD(0x00, 0, 5),
+ [F_IINLIM] = REG_FIELD(0x00, 0, 5),
/* REG01 */
[F_BHOT] = REG_FIELD(0x01, 6, 7),
[F_BCOLD] = REG_FIELD(0x01, 5, 5),
@@ -256,7 +256,7 @@ enum bq25890_table_ids {
/* range tables */
TBL_ICHG,
TBL_ITERM,
- TBL_IILIM,
+ TBL_IINLIM,
TBL_VREG,
TBL_BOOSTV,
TBL_SYSVMIN,
@@ -299,7 +299,7 @@ static const union {
/* TODO: BQ25896 has max ICHG 3008 mA */
[TBL_ICHG] = { .rt = {0, 5056000, 64000} }, /* uA */
[TBL_ITERM] = { .rt = {64000, 1024000, 64000} }, /* uA */
- [TBL_IILIM] = { .rt = {100000, 3250000, 50000} }, /* uA */
+ [TBL_IINLIM] = { .rt = {100000, 3250000, 50000} }, /* uA */
[TBL_VREG] = { .rt = {3840000, 4608000, 16000} }, /* uV */
[TBL_BOOSTV] = { .rt = {4550000, 5510000, 64000} }, /* uV */
[TBL_SYSVMIN] = { .rt = {3000000, 3700000, 100000} }, /* uV */
@@ -503,11 +503,11 @@ static int bq25890_power_supply_get_property(struct power_supply *psy,
break;

case POWER_SUPPLY_PROP_INPUT_CURRENT_LIMIT:
- ret = bq25890_field_read(bq, F_IILIM);
+ ret = bq25890_field_read(bq, F_IINLIM);
if (ret < 0)
return ret;

- val->intval = bq25890_find_val(ret, TBL_IILIM);
+ val->intval = bq25890_find_val(ret, TBL_IINLIM);
break;

case POWER_SUPPLY_PROP_VOLTAGE_NOW:
--
2.33.1
\
 
 \ /
  Last update: 2021-11-07 21:20    [W:0.094 / U:0.120 seconds]
©2003-2020 Jasper Spaans|hosted at Digital Ocean and TransIP|Read the blog|Advertise on this site