SubjectRe: [PATCH 2/3] thermal/drivers/mediatek/lvts_thermal: Honor sensors in immediate mode
From
Il 28/04/23 21:53, Nícolas F. R. A. Prado ha scritto:
> Each controller can be configured to operate on immediate or filtered
> mode. On filtered mode, the sensors are enabled by setting the
> corresponding bits in MONCTL0, while on immediate mode, by setting
> MSRCTL1.
>
> Previously, the code would set MSRCTL1 for all four sensors when
> configured to immediate mode, but given that the controller might not
> have all four sensors connected, this would cause interrupts to trigger
> for non-existent sensors. Fix this by handling the MSRCTL1 register
> analogously to the MONCTL0: only enable the sensors that were declared.
>
> Fixes: f5f633b18234 ("thermal/drivers/mediatek: Add the Low Voltage Thermal Sensor driver")
> Signed-off-by: Nícolas F. R. A. Prado <nfraprado@collabora.com>

Awesome!!!!!

Reviewed-by: AngeloGioacchino Del Regno <angelogioacchino.delregno@collabora.com>


\
 
 \ /