| Date | Tue, 27 Sep 2022 13:06:28 +0200 | Subject | Re: [PATCH v3 11/11] remoteproc: mediatek: Refine ipi handler error message | From | AngeloGioacchino Del Regno <> |
| |
Il 27/09/22 04:56, Tinghan Shen ha scritto: > The error message doesn't accurately reflect the cause of > the error. The error is due to a handler not being found, > not an invalid IPI ID. > > Signed-off-by: Tinghan Shen <tinghan.shen@mediatek.com>
Reviewed-by: AngeloGioacchino Del Regno <angelogioacchino.delregno@collabora.com>
|