lkml.org 
[lkml]   [2021]   [Sep]   [6]   [last100]   RSS Feed
Views: [wrap][no wrap]   [headers]  [forward] 
 
Messages in this thread
/
From
Subject[PATCH v2 0/3] iio: adc: Fix flags in sigma-delta drivers
Date
From: Alexandru Tachici <alexandru.tachici@analog.com>

In Sigma-Delta devices the SDO line is also used as an interrupt.
Leaving IRQ on level instead of falling might trigger a sample read
when the IRQ is enabled, as the SDO line is already low. Not sure
if SDO line will always imediately go high in ad_sd_buffer_postenable
before the IRQ is enabled.

Some sigma-delta drivers use wrong irq_flags specified in the
ad_sigma_delta_info struct. Add the flags corresponding to the
interrupt type specified in the data-sheets of each chip.

Alexandru Tachici (3):
iio: adc: ad7192: Add IRQ flag
iio: adc: ad7780: Fix IRQ flag
iio: adc: ad7793: Fix IRQ flag

Changelog:
- Changed commit messages

drivers/iio/adc/ad7192.c | 1 +
drivers/iio/adc/ad7780.c | 2 +-
drivers/iio/adc/ad7793.c | 2 +-
3 files changed, 3 insertions(+), 2 deletions(-)

--
2.25.1

\
 
 \ /