Messages in this thread Patch in this message | | | From | Boris Brezillon <> | Subject | [PATCH 02/16] mtd: nand: sunxi: fix clk rate calculation | Date | Mon, 7 Mar 2016 17:18:19 +0100 |
| |
Unlike what is specified in the Allwinner datasheets, the NAND clock rate is not equal to 2/T but 1/T. Fix the clock rate selection accordingly.
Signed-off-by: Boris Brezillon <boris.brezillon@free-electrons.com> --- drivers/mtd/nand/sunxi_nand.c | 8 +------- 1 file changed, 1 insertion(+), 7 deletions(-)
diff --git a/drivers/mtd/nand/sunxi_nand.c b/drivers/mtd/nand/sunxi_nand.c index 4d01e65..ab66d8d 100644 --- a/drivers/mtd/nand/sunxi_nand.c +++ b/drivers/mtd/nand/sunxi_nand.c @@ -1208,13 +1208,7 @@ static int sunxi_nand_chip_set_timings(struct sunxi_nand_chip *chip, /* Convert min_clk_period from picoseconds to nanoseconds */ min_clk_period = DIV_ROUND_UP(min_clk_period, 1000); - /* - * Convert min_clk_period into a clk frequency, then get the - * appropriate rate for the NAND controller IP given this formula - * (specified in the datasheet): - * nand clk_rate = 2 * min_clk_rate - */ - chip->clk_rate = (2 * NSEC_PER_SEC) / min_clk_period; + chip->clk_rate = NSEC_PER_SEC / min_clk_period; return 0; } -- 2.1.4
| |