Messages in this thread | | | Date | Wed, 9 Aug 2023 14:46:32 +0100 | Subject | Re: [PATCH 7/7] arm64: dts: qcom: apq8016-sbc: Enable camss for non-mezzanine cases | From | Bryan O'Donoghue <> |
| |
On 09/08/2023 13:11, Konrad Dybcio wrote: > On 9.08.2023 14:04, Bryan O'Donoghue wrote: >> When we have no camera mezzanine attached it is still possible to run the >> test-pattern generator of the CSID block. > Wasn't it broken? > > [...] >
So, running the TPG without the mezzaine has always been possible but, with the hard-coded sensor you'd fail to probe and never get user-space enumeration.
The fix is moving the sensor portion to its own mezzanine and enabling camss standalone.
I'll make that clearer in the log for V2.
Thx for the review.
--- bod
| |