Messages in this thread | | | Date | Wed, 16 Aug 2023 12:21:30 +0200 | Subject | Re: [PATCH v2] thermal/drivers/mediatek/lvts_thermal: Make readings valid in filtered mode | From | Daniel Lezcano <> |
| |
On 13/07/2023 17:42, Nícolas F. R. A. Prado wrote: > Currently, when a controller is configured to use filtered mode, thermal > readings are valid only about 30% of the time. > > Upon testing, it was noticed that lowering any of the interval settings > resulted in an improved rate of valid data. The same was observed when > decreasing the number of samples for each sensor (which also results in > quicker measurements). > > Retrying the read with a timeout longer than the time it takes to > resample (about 344us with these settings and 4 sensors) also improves > the rate. > > Lower all timing settings to the minimum, configure the filtering to > single sample, and poll the measurement register for at least one period > to improve the data validity on filtered mode. With these changes in > place, out of 100000 reads, a single one failed, ie 99.999% of the data > was valid. > > Reviewed-by: Chen-Yu Tsai <wenst@chromium.org> > Tested-by: Chen-Yu Tsai <wenst@chromium.org> > Signed-off-by: Nícolas F. R. A. Prado <nfraprado@collabora.com> > > ---
Applied, thanks