Messages in this thread | | | Date | Fri, 17 Feb 2023 17:13:30 -0600 | From | Rob Herring <> | Subject | Re: [PATCH v10 2/6] dt-bindings: opp: v2-qcom-level: Document CPR3 open/closed loop volt adjustment |
| |
On Fri, Feb 17, 2023 at 12:08:25PM +0100, Konrad Dybcio wrote: > CPR3 and newer can be fed per-OPP voltage adjustment values for both > open- and closed-loop paths to make better decisions about settling > on the final voltage offset target. Document these properties. > > Signed-off-by: Konrad Dybcio <konrad.dybcio@linaro.org> > --- > .../devicetree/bindings/opp/opp-v2-qcom-level.yaml | 14 ++++++++++++++ > 1 file changed, 14 insertions(+) > > diff --git a/Documentation/devicetree/bindings/opp/opp-v2-qcom-level.yaml b/Documentation/devicetree/bindings/opp/opp-v2-qcom-level.yaml > index a30ef93213c0..93cc88434dfe 100644 > --- a/Documentation/devicetree/bindings/opp/opp-v2-qcom-level.yaml > +++ b/Documentation/devicetree/bindings/opp/opp-v2-qcom-level.yaml > @@ -34,6 +34,20 @@ patternProperties: > minItems: 1 > maxItems: 2 > > + qcom,opp-cloop-vadj: > + description: | > + A value representing the closed-loop voltage adjustment value
A value?
> + associated with this OPP node. > + $ref: /schemas/types.yaml#/definitions/int32-array > + maxItems: 2
Or 2 values?
> + > + qcom,opp-oloop-vadj: > + description: | > + A value representing the open-loop voltage adjustment value > + associated with this OPP node. > + $ref: /schemas/types.yaml#/definitions/int32-array > + maxItems: 2 > + > required: > - opp-level > - qcom,opp-fuse-level > > -- > 2.39.1 >
| |