SubjectRe: [PATCH 4/4] ABI: sysfs-class-hwmon: document emergency/max/min temperature alarms
On Fri, Nov 17, 2023 at 07:40:37AM +0100, Javier Carrasco wrote:
> These attributes are widely used in the hwmon subsystem, but they still
> must be documented.
>
> Add tempY_emergency_alarm, tempY_max_alarm and tempY_min_alarm to the
> ABI documentation according to their current usage and access rights in
> the hwmon subsystem.
>
> Signed-off-by: Javier Carrasco <javier.carrasco.cruz@gmail.com>

Applied.

Thanks,
Guenter

\
 
 \ /