Messages in this thread | | | Date | Sat, 18 Nov 2023 09:46:05 -0800 | From | Guenter Roeck <> | Subject | Re: [PATCH 2/4] ABI: sysfs-class-hwmon: document missing humidity attributes |
| |
On Fri, Nov 17, 2023 at 07:40:35AM +0100, Javier Carrasco wrote: > All these attributes already exist and are used by the hwmon subsystem, > but they still must be documented. > > The missing attributes are the following: > - humidityY_alarm > - humidityY_fault > - humidityY_label > - humidityY_max > - humidityY_max_hyst > - humidityY_min > - humidityY_min_hyst > > Add the missing humidity attributes to the ABI documentation according > to their current usage and access rights in the hwmon subsystem. > > Signed-off-by: Javier Carrasco <javier.carrasco.cruz@gmail.com>
Applied.
Thanks, Guenter
| |