Messages in this thread | | | Date | Thu, 16 Nov 2023 17:59:59 +0100 | From | Köry Maincent <> | Subject | Re: [PATCH] usb: dwc3: don't reset device side if dwc3 was configured as host-only |
| |
On Thu, 16 Nov 2023 17:42:06 +0100 Köry Maincent <kory.maincent@bootlin.com> wrote:
> Hello, > > Similar issue with ZynqMP board related to that patch: > > xilinx-psgtr fd400000.phy: lane 3 (type 1, protocol 3): PLL lock timeout > phy phy-fd400000.phy.3: phy poweron failed --> -110 > dwc3 fe300000.usb: error -ETIMEDOUT: failed to initialize core > > With CONFIG_USB_DWC3_DUAL_ROLE and dr_mode = "host"; > > It may not be the correct fix.
Just figured out there was a patch (357191036889 usb: dwc3: Soft reset phy on probe for host) from Thinh aimed to fix it but the issue is still here on ZynqMP.
Regards,