Messages in this thread | | | Date | Sat, 21 Oct 2023 19:02:59 +0200 | Subject | Re: [PATCH v5 3/9] clk: qcom: apss-ipq-pll: Use stromer plus ops for stromer plus pll | From | Konrad Dybcio <> |
| |
On 10/20/23 08:19, Varadarajan Narayanan wrote: > The set rate and determine rate operations are different between > Stromer and Stromer Plus PLLs. Since the programming sequence is > different, the PLLs dont get configured properly and random, > inexplicable crash/freeze is seen. Hence, use stromer plus ops > for ipq_pll_stromer_plus. > > Reviewed-by: Dmitry Baryshkov <dmitry.baryshkov@linaro.org> > Acked-by: Stephen Boyd <sboyd@kernel.org> > Fixes: c7ef7fbb1ccf ("clk: qcom: apss-ipq-pll: add support for IPQ5332") > Signed-off-by: Kathiravan T <quic_kathirav@quicinc.com> > Signed-off-by: Varadarajan Narayanan <quic_varada@quicinc.com> > --- Reviewed-by: Konrad Dybcio <konrad.dybcio@linaro.org>
Konrad
| |