Messages in this thread | | | Date | Tue, 10 Oct 2023 16:57:12 +0100 | From | Jonathan Cameron <> | Subject | Re: [PATCH v4 11/17] staging: iio: resolver: ad2s1210: rename DOS reset min/max attrs |
| |
On Thu, 5 Oct 2023 19:50:28 -0500 David Lechner <dlechner@baylibre.com> wrote:
> The AD2S1210 has a programmable threshold for the degradation of signal > (DOS) mismatch fault. This fault is triggered when the difference in > amplitude between the sine and cosine inputs exceeds the threshold. > > The DOS reset min/max registers on the chip provide initial values > for internal tracking of the min/max of the monitor signal after the > fault register is cleared. > > This patch converts the custom device DOS reset min/max threshold > attributes custom event attributes on the monitor signal channel. > > The attributes now use millivolts instead of the raw register value in > accordance with the IIO ABI. > > Signed-off-by: David Lechner <dlechner@baylibre.com> Applied.
| |