Messages in this thread | | | Date | Tue, 10 Oct 2023 16:55:28 +0100 | From | Jonathan Cameron <> | Subject | Re: [PATCH v4 09/17] staging: iio: resolver: ad2s1210: convert DOS overrange threshold to event attr |
| |
On Thu, 5 Oct 2023 19:50:26 -0500 David Lechner <dlechner@baylibre.com> wrote:
> The AD2S1210 has a programmable threshold for the degradation of signal > (DOS) overrange fault. This fault is triggered when either the sine or > cosine input rises above the threshold voltage. > > This patch converts the custom device DOS overrange threshold attribute > to an event rising edge threshold attribute on the monitor signal > channel. > > The attribute now uses millivolts instead of the raw register value in > accordance with the IIO ABI. > > Emitting the event will be implemented in a later patch. > > Signed-off-by: David Lechner <dlechner@baylibre.com> Applied
| |