Am 2022-08-08 20:35, schrieb Guenter Roeck: > On 8/8/22 11:09, Daniel Lezcano wrote: >> The previous version of the OF code was returning -ENODEV if no >> thermal zones description was found or if the lookup of the sensor in >> the thermal zones was not found. >> >> The backend drivers are expecting this return value as an information >> about skipping the sensor initialization and considered as normal. >> >> Fix the return value by replacing -EINVAL by -ENODEV >> >> Signed-off-by: Daniel Lezcano <daniel.lezcano@linaro.org> >> --- >> drivers/thermal/thermal_of.c | 4 ++-- >> 1 file changed, 2 insertions(+), 2 deletions(-) >> >> diff --git a/drivers/thermal/thermal_of.c >> b/drivers/thermal/thermal_of.c >> index 368eb58e97cf..4210c18ef7b2 100644 >> --- a/drivers/thermal/thermal_of.c >> +++ b/drivers/thermal/thermal_of.c >> @@ -329,7 +329,7 @@ static struct device_node >> *of_thermal_zone_find(struct device_node *sensor, int >> np = of_find_node_by_name(NULL, "thermal-zones"); >> if (!np) { >> pr_err("Unable to find thermal zones description\n"); > > I really don't like that error message: People will see it (and > complain) > whenever a sensor registers and there is no thermal zone, even though > that > is perfectly normal (see description above).
I can second that, and there actually two error messages:
[ 6.156983] thermal_sys: Unable to find thermal zones description [ 6.163125] thermal_sys: Failed to find thermal zone for hwmon id=0
On the sl28 board with the qoriq_thermal driver: [ 1.917940] thermal_sys: Failed to find thermal zone for tmu id=2 [ 1.929231] thermal_sys: Failed to find thermal zone for tmu id=3 [ 1.940519] thermal_sys: Failed to find thermal zone for tmu id=4 [ 1.951814] thermal_sys: Failed to find thermal zone for tmu id=5 [ 1.963109] thermal_sys: Failed to find thermal zone for tmu id=6 [ 1.974399] thermal_sys: Failed to find thermal zone for tmu id=7 [ 1.985690] thermal_sys: Failed to find thermal zone for tmu id=8 [ 1.996980] thermal_sys: Failed to find thermal zone for tmu id=9 [ 2.008274] thermal_sys: Failed to find thermal zone for tmu id=10 [ 2.019656] thermal_sys: Failed to find thermal zone for tmu id=11 [ 2.031037] thermal_sys: Failed to find thermal zone for tmu id=12 [ 2.048942] thermal_sys: Failed to find thermal zone for tmu id=13 [ 2.060320] thermal_sys: Failed to find thermal zone for tmu id=14 [ 2.071700] thermal_sys: Failed to find thermal zone for tmu id=15
Btw. the driver seems to always register 16 sensors regardless how many the actual hardware has (or rather: are described in the DT).
-michael
| |