On 04. 08. 22, 16:35, Shenwei Wang wrote:
>> On 02. 08. 22, 18:38, Shenwei Wang wrote:
>>> The setting of RS485 RTS polarity is inverse in the current driver.
>>>
>>> When the property of 'rs485-rts-active-low' is enabled in the dts
>>> node, the RTS signal should be LOW during sending. Otherwise, if there
>>> is no such a property, the RTS should be HIGH during sending.
>>
>> What commit this fixes? I.e. I am missing a Fixes tag below.
>
> It is a fix for the following commit:
> Fixes: 03895cf41d18 ("tty: serial: fsl_lpuart: Add support for RS-485")
>
> Should I send out a new version to update it?

It's up to Greg, but I guess so.

--