lkml.org 
[lkml]   [2022]   [Jul]   [23]   [last100]   RSS Feed
Views: [wrap][no wrap]   [headers]  [forward] 
 
Messages in this thread
/
From
Subject[PATCH v4 0/5] Add support for pressure sensor Bosch BMP380
Date
This patchset adds BMP380 variant to the already existing drivers for
the Bosch BMP180/280 pressure sensors.

Patch 1 adds references and sensor id to the devicetree bindings docs.
Patch 2 is a minor refactor simplifying driver initialization logic
to facilitate the integration of the new sensor variant extending the
information stored in the "chip_info" struct.
Patch 3 fixes DMA unsafe regmap_bulk_* calls reported by Jonathan Cameron
<jic23@kernel.org>.
Patch 4 adds the basic logic to initialize and read measurements from
the sensor.
Patch 5 adds advanced configurable features such as sampling frequency
and IIR filter through the IIO sysfs ABI.

Changes in v4:
- Patch 4 and 2: Merged v3 patch 2 (Kconfig refs update) into this patch.
- Patch 3: Added patch fixing unsafe DMA regmap_bulk_* calls reported by
Jonathan Cameron <jic23@kernel.org>.
- Patch 4: Fixed DMA unsafe buffers used on regmap_bulk_* calls reported
by Jonathan Cameron <jic23@kernel.org>.

Changes in v3:
- Patch 2: Fixed incorrect abbreviation.
- Patch 3: use dev_err_probe helper to handle error initializing sensor.
- Patch 4: Fixed kernel test robot warning provoked by missing include.
- Patch 4: Fixed bug reported by Dan Carpenter <dan.carpenter@oracle.com>.
- Patch 5: Fixed formatting and typos on multiple comments.
- Patch 5: Fixed missing boolean initialization reported by
Andy Shevchenko <andy.shevchenko@gmail.com>.
- Patch 5: Replaced duplicated comments with a single comment containing
a brief explantation in a shared location.
- Patch 5: Dropped incorrect use of unlikely macro.

Changes in v2:
- Added patch 2 updating Kconfig with references to new sensor.
- Patch 3 adds changes proposed by Jonathan Cameron <jic23@kernel.org>
to declutter and unify configuration logic for the different sensors
extending "chip_info" struct with default configuration parameters.
- Patch 4: store temperature and pressure adc values on 3 byte array
instead of using the type __le32. Uses function get_unaligned_le24
to convert the little-endian encoded 3 byte value to an integer.
- Patch 4: drops custom macro le16_from_bytes and use get_unaligned_le16.
- Patch 4: generate masks using GENMASK macro.
- Patch 4: use FIELD_PREP to generate bitfields for registries.
- Patch 4: dropped stray formatting change.
- Patch 5: adds sanity checks in bmp280_read_raw for channel properties
only available in the BMP380.
- Patch 5: on bmp280_write_* checks if a problem ocurred committing new
configuration and tries to restore previous working configuration
to keep the sensor in a previous working state.
- Patch 5: refactored bmp380_chip_config to only check for configuration
errors when a configuration change is detected.
- Patch 5: improved invalid configuration detection on BMP380 restarting
measurement loop to force a new measurement after the configuration is
updated.

Angel Iglesias (5):
dt-bindings: iio: pressure: bmp085: Add BMP380 compatible string
iio: pressure: bmp280: simplify driver initialization logic
iio: pressure: bmp280: Fix alignment for DMA safety
iio: pressure: bmp280: Add support for BMP380 sensor family
iio: pressure: bmp280: Add more tunable config parameters for BMP380

.../bindings/iio/pressure/bmp085.yaml | 4 +-
drivers/iio/pressure/Kconfig | 6 +-
drivers/iio/pressure/bmp280-core.c | 884 ++++++++++++++++--
drivers/iio/pressure/bmp280-i2c.c | 5 +
drivers/iio/pressure/bmp280-regmap.c | 55 ++
drivers/iio/pressure/bmp280-spi.c | 5 +
drivers/iio/pressure/bmp280.h | 83 ++
7 files changed, 937 insertions(+), 105 deletions(-)


base-commit: 180c6cb6b9b79c55b79e8414f4c0208f2463af7d
--
2.37.1

\
 
 \ /
  Last update: 2022-07-23 19:38    [W:0.108 / U:0.772 seconds]
©2003-2020 Jasper Spaans|hosted at Digital Ocean and TransIP|Read the blog|Advertise on this site