Messages in this thread | | | From | Stephen Boyd <> | Date | Thu, 17 Mar 2022 17:11:00 -0400 | Subject | Re: [PATCH v6 1/5] drm/msm/disp/dpu1: set mdp clk to the maximum frequency in opp table during probe |
| |
Quoting Vinod Polimera (2022-03-14 07:46:53) > use max clock during probe/bind sequence from the opp table. > The clock will be scaled down when framework sends an update.
Capitalize 'use'.
Why is it important to use max frequency during probe/bind? Does not setting the clk rate during probe mean that we'll never use the max rate? Does it speed things up during probe?
| |