lkml.org 
[lkml]   [2022]   [Jan]   [14]   [last100]   RSS Feed
Views: [wrap][no wrap]   [headers]  [forward] 
 
Messages in this thread
/
From
Subject[PATCH v1 0/2] Enable i.MX7 SOLO temperature sensor
Date
To be able to read the T junction on i.MX CPU the imx-cpufreq-dt needs to be
loaded, however this is currently not the case for i.MX7S given that it does
have only one operating frequency.

Add "fsl,imx7s" to cpufreq-dt-platdev blocklist and a single frequency
operating point to the CPU.

With that it is now possible to correctly read the CPU T junction.

Tested on Toradex Colibri iMX7S

[ 6.232577] imx-cpufreq-dt imx-cpufreq-dt: cpu speed grade 0 mkt segment 1 supported-hw 0x1 0x2
...
[ 6.880624] imx_thermal 30360000.anatop:tempmon: Extended Commercial CPU temperature grade - max:105C critical:100C passive:95C

root@colibri-imx7-02983025:~# cat /sys/class/thermal/thermal_zone0/temp
38000


Denys Drozdov (1):
ARM: dts: imx7s: Define operating points table for cpufreq

Stefan Agner (1):
cpufreq: Add i.MX7S to cpufreq-dt-platdev blocklist

arch/arm/boot/dts/imx7s.dtsi | 16 ++++++++++++++++
drivers/cpufreq/cpufreq-dt-platdev.c | 2 ++
2 files changed, 18 insertions(+)

--
2.25.1

\
 
 \ /
  Last update: 2022-01-14 16:20    [W:2.312 / U:0.020 seconds]
©2003-2020 Jasper Spaans|hosted at Digital Ocean and TransIP|Read the blog|Advertise on this site