lkml.org 
[lkml]   [2021]   [Jul]   [6]   [last100]   RSS Feed
Views: [wrap][no wrap]   [headers]  [forward] 
 
Messages in this thread
Patch in this message
/
From
Subject[PATCH net] can: j1939: j1939_xtp_rx_dat_one(): fix rxtimer value between consecutive TP.DT to 750ms
Date
For receive side, the max time interval between two consecutive TP.DT
should be 750ms.

Fixes: 9d71dd0c7009 ("can: add support of SAE J1939 protocol")
Signed-off-by: Zhang Changzhong <zhangchangzhong@huawei.com>
---
net/can/j1939/transport.c | 2 +-
1 file changed, 1 insertion(+), 1 deletion(-)

diff --git a/net/can/j1939/transport.c b/net/can/j1939/transport.c
index c3946c3..4113229 100644
--- a/net/can/j1939/transport.c
+++ b/net/can/j1939/transport.c
@@ -1869,7 +1869,7 @@ static void j1939_xtp_rx_dat_one(struct j1939_session *session,
if (!session->transmission)
j1939_tp_schedule_txtimer(session, 0);
} else {
- j1939_tp_set_rxtimeout(session, 250);
+ j1939_tp_set_rxtimeout(session, 750);
}
session->last_cmd = 0xff;
consume_skb(se_skb);
--
2.9.5
\
 
 \ /
  Last update: 2021-07-06 12:54    [W:0.037 / U:0.172 seconds]