Messages in this thread | | | Date | Tue, 1 Jun 2021 18:47:34 +0800 | From | Wong Vee Khee <> | Subject | Re: [RFC net-next 0/2] Introduce MDIO probe order C45 over C22 |
| |
On Tue, May 25, 2021 at 03:34:34PM +0200, Andrew Lunn wrote: > On Tue, May 25, 2021 at 01:58:03PM +0800, Wong Vee Khee wrote: > > Synopsys MAC controller is capable of pairing with external PHY devices > > that accessible via Clause-22 and Clause-45. > > > > There is a problem when it is paired with Marvell 88E2110 which returns > > PHY ID of 0 using get_phy_c22_id(). We can add this check in that > > function, but this will break swphy, as swphy_reg_reg() return 0. [1] > > Is it possible to identify it is a Marvell PHY? Do any of the other > C22 registers return anything unique? I'm wondering if adding > .match_phy_device to genphy would work to identify it is a Marvell PHY > and not bind to it. Or we can turn it around, make the > .match_phy_device specifically look for the fixed-link device by > putting a magic number in one of the vendor registers. >
I checked the Marvell and did not see any unique register values. Also, since get_phy_c22_id() returns a *phy_id== 0, it is not bind to any PHY driver, so I don't think adding the match_phy_device check in getphy would help.