Messages in this thread | | | Date | Tue, 25 May 2021 15:34:34 +0200 | From | Andrew Lunn <> | Subject | Re: [RFC net-next 0/2] Introduce MDIO probe order C45 over C22 |
| |
On Tue, May 25, 2021 at 01:58:03PM +0800, Wong Vee Khee wrote: > Synopsys MAC controller is capable of pairing with external PHY devices > that accessible via Clause-22 and Clause-45. > > There is a problem when it is paired with Marvell 88E2110 which returns > PHY ID of 0 using get_phy_c22_id(). We can add this check in that > function, but this will break swphy, as swphy_reg_reg() return 0. [1]
Is it possible to identify it is a Marvell PHY? Do any of the other C22 registers return anything unique? I'm wondering if adding .match_phy_device to genphy would work to identify it is a Marvell PHY and not bind to it. Or we can turn it around, make the .match_phy_device specifically look for the fixed-link device by putting a magic number in one of the vendor registers.