Messages in this thread Patch in this message | | | From | richard.gong@linux ... | Subject | [PATCHv1] firmware: stratix10-svc: reset COMMAND_RECONFIG_FLAG_PARTIAL to 0 | Date | Wed, 27 Jan 2021 15:43:21 -0600 |
| |
From: Richard Gong <richard.gong@intel.com>
Clean up COMMAND_RECONFIG_FLAG_PARTIAL flag by resetting it to 0, which aligns with the firmware settings.
Signed-off-by: Richard Gong <richard.gong@intel.com> --- include/linux/firmware/intel/stratix10-svc-client.h | 6 +++--- 1 file changed, 3 insertions(+), 3 deletions(-)
diff --git a/include/linux/firmware/intel/stratix10-svc-client.h b/include/linux/firmware/intel/stratix10-svc-client.h index ebc2956..1ffb982 100644 --- a/include/linux/firmware/intel/stratix10-svc-client.h +++ b/include/linux/firmware/intel/stratix10-svc-client.h @@ -51,12 +51,12 @@ #define SVC_STATUS_NO_SUPPORT 6 /* - * Flag bit for COMMAND_RECONFIG + * Flag for COMMAND_RECONFIG, in bit number * * COMMAND_RECONFIG_FLAG_PARTIAL: - * Set to FPGA configuration type (full or partial). + * Set for partial configuration. */ -#define COMMAND_RECONFIG_FLAG_PARTIAL 1 +#define COMMAND_RECONFIG_FLAG_PARTIAL 0 /* * Timeout settings for service clients: -- 2.7.4
| |