lkml.org 
[lkml]   [2020]   [Jun]   [12]   [last100]   RSS Feed
Views: [wrap][no wrap]   [headers]  [forward] 
 
Messages in this thread
/
SubjectRe: [PATCH v3 2/2] ASoC: tas2562: Update shutdown GPIO property
From
Date
Mark

On 6/12/20 11:22 AM, Mark Brown wrote:
> On Fri, Jun 12, 2020 at 11:18:57AM -0500, Dan Murphy wrote:
>> On 6/12/20 11:09 AM, Mark Brown wrote:
>>> On Fri, Jun 12, 2020 at 11:06:03AM -0500, Dan Murphy wrote:
>>>> - tas2562->sdz_gpio = devm_gpiod_get_optional(dev, "shut-down-gpio",
>>>> + tas2562->sdz_gpio = devm_gpiod_get_optional(dev, "shutdown",
>>>> GPIOD_OUT_HIGH);
>>> This also changes the name from shut-down to shutdown which will be
>>> incompatible (IIRC we do try -gpio as well as -gpios).
>> Yes the non-standardish name was highlighted by Rob[1].
> Yes, but we released with it so it's an ABI now and we should still
> support the old name.

Well should we then just revert back to the non-standard name and just
fix up the code?

Or should we support both properties?

Dan

\
 
 \ /