Messages in this thread | | | Date | Fri, 12 Jun 2020 17:22:00 +0100 | From | Mark Brown <> | Subject | Re: [PATCH v3 2/2] ASoC: tas2562: Update shutdown GPIO property |
| |
On Fri, Jun 12, 2020 at 11:18:57AM -0500, Dan Murphy wrote: > On 6/12/20 11:09 AM, Mark Brown wrote: > > On Fri, Jun 12, 2020 at 11:06:03AM -0500, Dan Murphy wrote:
> > > - tas2562->sdz_gpio = devm_gpiod_get_optional(dev, "shut-down-gpio", > > > + tas2562->sdz_gpio = devm_gpiod_get_optional(dev, "shutdown", > > > GPIOD_OUT_HIGH);
> > This also changes the name from shut-down to shutdown which will be > > incompatible (IIRC we do try -gpio as well as -gpios).
> Yes the non-standardish name was highlighted by Rob[1].
Yes, but we released with it so it's an ABI now and we should still support the old name. [unhandled content-type:application/pgp-signature] | |