Messages in this thread | | | Subject | Re: [PATCH 2/3] devfreq: exynos-bus: convert to use dev_pm_opp_set_rate() | From | Kamil Konieczny <> | Date | Thu, 11 Jul 2019 15:36:50 +0200 |
| |
On 10.07.2019 19:04, Krzysztof Kozlowski wrote: > On Mon, 8 Jul 2019 at 16:12, <k.konieczny@partner.samsung.com> wrote: >> >> From: Kamil Konieczny <k.konieczny@partner.samsung.com> >> >> Reuse opp core code for setting bus clock and voltage. As a side >> effect this allow useage of coupled regulators feature (required >> for boards using Exynos5422/5800 SoCs) because dev_pm_opp_set_rate() >> uses regulator_set_voltage_triplet() for setting regulator voltage >> while the old code used regulator_set_voltage_tol() with fixed >> tolerance. This patch also removes no longer needed parsing of DT >> property "exynos,voltage-tolerance" (no Exynos devfreq DT node uses > > Please also update the bindings in such case. Both with removal of > unused property and with example/recommended regulator couplings.
Right, I will remove it.
-- Best regards, Kamil Konieczny Samsung R&D Institute Poland
| |