Messages in this thread | | | Date | Wed, 4 Dec 2019 23:19:50 -0800 | Subject | [PATCH v3 0/3] thermal: introduce by-name softlink | From | Wei Wang <> |
| |
The paths thermal_zone%d and cooling_device%d are not intuitive and the numbers are subject to change due to device tree change. This usually leads to tree traversal in userspace code. The patch creates `tz-by-name' and `cdev-by-name' for thermal zone and cooling_device respectively.
Changes since v1 [1]: * Split cooling device registration into a seperate patch Changes since v2 [2]: * Split improve error message in thermal zone registration
[1]: v1: https://lore.kernel.org/patchwork/patch/1139450/ [2]: v2: https://lkml.org/lkml/2019/12/4/1291
Wei Wang (3): thermal: prevent cooling device with no type to be registered thermal: improve error message in thermal zone registration thermal: create softlink by name for thermal_zone and cooling_device
drivers/thermal/thermal_core.c | 55 +++++++++++++++++++++++++++------- 1 file changed, 44 insertions(+), 11 deletions(-)
-- 2.24.0.393.g34dc348eaf-goog
| |