Messages in this thread | | | Date | Fri, 10 Aug 2018 13:30:35 +0100 | From | Quentin Perret <> | Subject | Re: [PATCH v5 03/14] PM: Introduce an Energy Model management framework |
| |
On Friday 10 Aug 2018 at 13:13:22 (+0200), Rafael J. Wysocki wrote: > Something able to say how the numbers used by EM and IPA are related. :-) > > Do you think that IPA and EM will always need to use the same set of data for > the CPU?
Hmm, I would say yes. Both EAS and IPA basically need some sort of <frequency, power> table, so hopefully the EM framework can provide them with that :-).
If the EM framework doesn't accommodate the needs of its two users, then something needs fixing ... Did you have something specific in mind ?
Thanks, Quentin
| |