Messages in this thread | | | From | "Rafael J. Wysocki" <> | Date | Sun, 12 Aug 2018 11:49:40 +0200 | Subject | Re: [PATCH v5 03/14] PM: Introduce an Energy Model management framework |
| |
On Fri, Aug 10, 2018 at 2:30 PM Quentin Perret <quentin.perret@arm.com> wrote: > > On Friday 10 Aug 2018 at 13:13:22 (+0200), Rafael J. Wysocki wrote: > > Something able to say how the numbers used by EM and IPA are related. :-) > > > > Do you think that IPA and EM will always need to use the same set of data for > > the CPU? > > Hmm, I would say yes. Both EAS and IPA basically need some sort of > <frequency, power> table, so hopefully the EM framework can provide them > with that :-). > > If the EM framework doesn't accommodate the needs of its two users, then > something needs fixing ... Did you have something specific in mind ?
Not really. :-)
| |