Messages in this thread Patch in this message | | | From | Arnd Bergmann <> | Subject | [PATCH] clk: sunxi-ng: always select CCU_GATE | Date | Thu, 27 Apr 2017 13:02:31 +0200 |
| |
When the base driver is enabled but all SoC specific drivers are turned off, we now get a build error after code was added to always refer to the clk gates:
drivers/clk/built-in.o: In function `ccu_pll_notifier_cb': :(.text+0x154f8): undefined reference to `ccu_gate_helper_disable' :(.text+0x15504): undefined reference to `ccu_gate_helper_enable'
This changes the Kconfig to always require the gate code to be built-in when CONFIG_SUNXI_CCU is set.
Fixes: 02ae2bc6febd ("clk: sunxi-ng: Add clk notifier to gate then ungate PLL clocks") Signed-off-by: Arnd Bergmann <arnd@arndb.de> --- drivers/clk/sunxi-ng/Kconfig | 2 +- 1 file changed, 1 insertion(+), 1 deletion(-)
diff --git a/drivers/clk/sunxi-ng/Kconfig b/drivers/clk/sunxi-ng/Kconfig index 64088e599404..b0d551a8efe4 100644 --- a/drivers/clk/sunxi-ng/Kconfig +++ b/drivers/clk/sunxi-ng/Kconfig @@ -16,7 +16,7 @@ config SUNXI_CCU_FRAC bool config SUNXI_CCU_GATE - bool + def_bool y config SUNXI_CCU_MUX bool -- 2.9.0
| |