Messages in this thread | | | Date | Wed, 13 May 2015 08:31:52 -0700 | From | "" <> | Subject | Re: [PATCH v3] w1: introduce an ability to specify microseconds bus scanning intervals |
| |
On Wed, May 13, 2015 at 06:00:55PM +0300, Evgeniy Polyakov wrote: > Hi > > 12.05.2015, 22:30, "Dmitry Khromov" <dk@icelogic.net>: > > Some of 1-Wire devices commonly associated with physical access control > > systems are attached/generate presence for as short as 100 ms - hence > > the tens-to-hundreds milliseconds scan intervals are required. > > > > Signed-off-by: Dmitry Khromov <dk@icelogic.net> > > Greg, please pull it upstream > Acked-by: Evgeniy Polyakov <zbr@ioremap.net>
Ok, will do.
| |