Messages in this thread | | | From | Evgeniy Polyakov <> | Subject | Re: [PATCH v3] w1: introduce an ability to specify microseconds bus scanning intervals | Date | Wed, 13 May 2015 18:00:55 +0300 |
| |
Hi
12.05.2015, 22:30, "Dmitry Khromov" <dk@icelogic.net>: > Some of 1-Wire devices commonly associated with physical access control > systems are attached/generate presence for as short as 100 ms - hence > the tens-to-hundreds milliseconds scan intervals are required. > > Signed-off-by: Dmitry Khromov <dk@icelogic.net>
Greg, please pull it upstream Acked-by: Evgeniy Polyakov <zbr@ioremap.net>
| |