Messages in this thread | | | Date | Wed, 10 Dec 2014 11:59:21 +0100 | From | Sylwester Nawrocki <> | Subject | Re: [PATCH/RFC v9 06/19] DT: Add documentation for the mfd Maxim max77693 |
| |
On 10/12/14 11:02, Jacek Anaszewski wrote: >>>> +Optional properties: >>>> >>> +- maxim,fleds : Array of current outputs in order: fled1, fled2.
s/current outputs/LED current regulator outputs used/ ?
>>>> >>> + Note: both current outputs can be connected to a single led
s/led/LED ? And there seem to be other similar occurrences that would need to be put in upper case.
>>>> >>> + Possible values: >>>> >>> + MAX77693_LED_FLED_UNUSED - the output is left disconnected, >>>> >>> + MAX77693_LED_FLED_USED - a diode is connected to the output.
As noted below, I would simply use 0/1 for these.
>>> >> >>> >> As you have a LED sub-nodes for each LED already, isn't this redundant? >> > >> > Well, it seems so :) > > I agreed here recklessly. This property allows to describe the > situation when one LED is connected to both outputs. Single sub-node > can describe two type of designs: one LED connected to a single > output or one LED connected to both outputs. Therefore additional > property is needed to assess what is the actual case.
How about renaming "maxim,fleds" to "maxim,active-outputs" ? And simply using 0 and 1 to indicate if one is used or not, rather than defining macros for these true/false values ?
-- Regards, Sylwester
| |