Messages in this thread | | | Date | Mon, 22 Apr 2013 17:53:53 +0530 | From | Laxman Dewangan <> | Subject | Re: [PATCH RESEND] regulator: palmas: Fix off-by-one for ramp_delay and register value mapping |
| |
On Monday 22 April 2013 03:52 PM, Axel Lin wrote: > Datasheet says: > Time Step (TSTEP) selection, when changing the output voltage, the new value is > reached through successive voltage steps (if not bypassed). The equivalent > programmable slew rate of the output voltage is: > > TSTEP[1:0]: 00 Jump (no slope control) > TSTEP[1:0]: 01 10mV/us > TSTEP[1:0]: 10 5mV/us (default) > TSTEP[1:0]: 11 2.5mV/us > > Signed-off-by: Axel Lin <axel.lin@ingics.com> > ---
Acked-by: Laxman Dewangan <ldewangan@nvidia.com>
| |