SubjectRe: [PATCH RESEND] regulator: palmas: Fix off-by-one for ramp_delay and register value mapping
On Monday 22 April 2013 03:52 PM, Axel Lin wrote:
> Datasheet says:
> Time Step (TSTEP) selection, when changing the output voltage, the new value is
> reached through successive voltage steps (if not bypassed). The equivalent
> programmable slew rate of the output voltage is:
>
> TSTEP[1:0]: 00 Jump (no slope control)
> TSTEP[1:0]: 01 10mV/us
> TSTEP[1:0]: 10 5mV/us (default)
> TSTEP[1:0]: 11 2.5mV/us
>
> Signed-off-by: Axel Lin <axel.lin@ingics.com>
> ---

Acked-by: Laxman Dewangan <ldewangan@nvidia.com>



\
 
 \ /