Subject[PATCH 3.12 111/116] s390/time: fix get_tod_clock_ext inline assembly
Date
3.12-stable review patch.  If anyone has any objections, please let me know.

------------------

From: Martin Schwidefsky <schwidefsky@de.ibm.com>

commit 7ab64a85e1a009046f97413a573e83fd85f7804d upstream.

The get_tod_clock_ext inline assembly does not specify its output
operands correctly. This can cause incorrect code to be generated.

Signed-off-by: Martin Schwidefsky <schwidefsky@de.ibm.com>
Signed-off-by: Greg Kroah-Hartman <gregkh@linuxfoundation.org>

---
arch/s390/include/asm/timex.h | 6 ++++--
1 file changed, 4 insertions(+), 2 deletions(-)

--- a/arch/s390/include/asm/timex.h
+++ b/arch/s390/include/asm/timex.h
@@ -71,9 +71,11 @@ static inline void local_tick_enable(uns

typedef unsigned long long cycles_t;

-static inline void get_tod_clock_ext(char *clk)
+static inline void get_tod_clock_ext(char clk[16])
{
- asm volatile("stcke %0" : "=Q" (*clk) : : "cc");
+ typedef struct { char _[sizeof(clk)]; } addrtype;
+
+ asm volatile("stcke %0" : "=Q" (*(addrtype *) clk) : : "cc");
}

static inline unsigned long long get_tod_clock(void)



\
 
 \ /