Messages in this thread Patch in this message | | | From | Russ Gorby <> | Subject | [PATCH 1/6] serial: ifx6x60: fixed call to tty_port_init | Date | Mon, 7 Feb 2011 12:02:27 -0800 |
| |
The port ops must be set AFTER calling port init as that function zeroes the structure
Signed-off-by: Russ Gorby <russ.gorby@intel.com> --- drivers/tty/serial/ifx6x60.c | 2 +- 1 files changed, 1 insertions(+), 1 deletions(-)
diff --git a/drivers/tty/serial/ifx6x60.c b/drivers/tty/serial/ifx6x60.c index c42de71..972c04d 100644 --- a/drivers/tty/serial/ifx6x60.c +++ b/drivers/tty/serial/ifx6x60.c @@ -798,8 +798,8 @@ static int ifx_spi_create_port(struct ifx_spi_device *ifx_dev) goto error_ret; } - pport->ops = &ifx_tty_port_ops; tty_port_init(pport); + pport->ops = &ifx_tty_port_ops; ifx_dev->minor = IFX_SPI_TTY_ID; ifx_dev->tty_dev = tty_register_device(tty_drv, ifx_dev->minor, &ifx_dev->spi_dev->dev); -- 1.7.3.4
| |