Messages in this thread | | | Subject | Re: signal(SIGFPE,SIG_IGN) causes endless loop | Date | Tue, 23 Apr 1996 13:40:28 +0000 (ZOM) | From | "Paul Slootman" <> |
| |
albert@ccs.neu.edu wrote:
>OK, what about x86 OSs? This could affect iBCS a bit.
SVR4 x86 (Siemens Nixdorf Sinix 5.41B): endless loop
Excerpt from truss: signal(SIGFPE, SIG_IGN) = SIG_DFL Incurred fault #8, FLTIZDIV %pc = 0x08048446 siginfo: SIGFPE FPE_INTDIV addr=0x00000000 Received signal #8, SIGFPE [ignored] siginfo: SIGFPE FPE_INTDIV addr=0x00000000 Incurred fault #8, FLTIZDIV %pc = 0x08048446 siginfo: SIGFPE FPE_INTDIV addr=0x00000000 Received signal #8, SIGFPE [ignored] siginfo: SIGFPE FPE_INTDIV addr=0x00000000 [repeated ad nauseam] Paul Slootman -- Murphy Software, Enschede, The Netherlands There is no such thing work: paul@wau.mis.ah.nl / paul@murphy.nl as a coincidence. home: paul@wurtel.hobby.nl
| |