Messages in this thread Patch in this message | | | Date | Thu, 18 Apr 1996 18:32:42 +0100 (BST) | From | Alex Kiernan <> | Subject | Patch to fix Sanyo CRD-250S with multiple LUNs enabled |
| |
I just enabled LUNs in the 1.3.91 kernel (got a Nakamichi disk changer to play with). The existing Sanyo CD in the machine caused a failed request sense, the kernel then tries to reset (which seems to be broke on a aha152x at least - after the 'reset' it was big red button time).
--- drivers/scsi/scsi.c~ Thu Apr 18 14:18:24 1996 +++ drivers/scsi/scsi.c Thu Apr 18 18:10:15 1996 @@ -248,6 +248,9 @@ {"MICROP", "4110", "*", BLIST_NOTQ}, /* Buggy Tagged Queuing */ {"NEC","CD-ROM DRIVE:841","1.0", BLIST_NOLUN}, /* Locks-up when LUN>0 polled. */ {"RODIME","RO3000S","2.33", BLIST_NOLUN}, /* Locks up if polled for lun != 0 */ +{"SANYO", "CRD-250S", "1.20", BLIST_NOLUN}, /* causes failed REQUEST SENSE on lun 1 + * for aha152x controller, which causes + * SCSI code to reset bus.*/ {"SEAGATE", "ST157N", "\004|j", BLIST_NOLUN}, /* causes failed REQUEST SENSE on lun 1 * for aha152x controller, which causes * SCSI code to reset bus.*/ -- Alex Kiernan - alex@hisoft.co.uk HiSoft Systems Tel: +44 1525 718181 Fax: +44 1525 713716 The Old School, Greenfield, Bedford, MK45 5DE, UK
| |