Messages in this thread | | | From | (TANAKA Yoshitomo) | Subject | Re: 1.3.89 BusLogic driver problem | Date | 16 Apr 1996 02:35:38 +0900 |
| |
Oh, I realized 'BusLogic_GlobalOptions'. Setting it to 31 and got more infomation. I transcribed followings by hand. I hope there isn't mistake....
>BusLogic_Probe(0x330): Status 0x30 >BusLogic_Probe(0x330): Geometry 0x55 >BusLogic_HardReset(0x330): Diagnostic Active, Status 0xB0 >BusLogic_HardReset(0x330): Diagnostic Completed, Status 0x30 >BusLogic_HardReset(0x330): Host Adapter Ready, Status 0x30 >BusLogic_Command(8D) Status = 30: 14 ==> 14: 45 DC 00 20 00 00 00 00 00 00 32 31 20 00 >BusLogic_Check(0x330): Result 14 >scsi: ***** BusLogic SCSI Driver Version 1.3.2 of 13 April 1996 ***** >scsi: Copyright 1995 by Leonard N. Zubkoff <lnz@dandelion.com> >BusLogic_Command(04) Status = 30: 4 ==> 4: 41 41 34 32 >BusLogic_Command(0B) Status = 30: 3 ==> 3: 00 04 07 >BusLogic_Command(0D) Status = 30: 31 ==> 31: 03 00 07 04 00 00 00 00 00 00 00 00 00 00 00 00 FF 42 44 45 00 00 00 00 00 00 00 00 00 00 00 >BusLogic_Command(8D) Status = 30: 14 ==> 14: 45 DC 00 20 00 00 00 00 00 00 32 31 20 00 >BusLogic_Command(8B) Status = 30: 5 ==> 5: 34 34 78 43 20 >BusLogic_Command(84) Status = 30: 1 ==> 1: 31 >BusLogic_Command(85) Status = 30: 1 ==> 1: 20 >BusLogic_Command(91) Status = 30: 1 ==> 1: 3A >scsi0: Configuring BusLogic Model BT-44xC VESA SCSI Host Adapter >scsi0: Firmware Version: 4.21, I/O Address: 0x330, IRQ Channel: 11/Edge >scsi0: DMA Channel: None, BIOS Address: 0xDC000, Host Adapter SCSI ID: 7 >scsi0: Scatter/Gather Limit: 128 of 8192 segments, Parity Checking: Enabled >scsi0: Synchronous Initiation: Enabled, Extended Disk Translation: Disabled >scsi0: Disconnect/Reconnect: Enabled, Tagged Queuing: Disabled >scsi0: Total Queue Depth: 100, Mailboxes: 255, Initial CCBs: 64 >scsi0: Tagged Queue Depth: Automatic, Untagged Queue Depth: 3 >scsi0: Host Adapter SCSI Bus Termination: Disabled >scsi0: Error Recovery Strategy: Default >BusLogic_Command(81) Status = 10: 0 ==> 0: >BusLogic_Command(8F) Status = 10: 0 ==> 0: >scsi0: *** BusLogic BT-44xC Initialized Successfully *** >BusLogic_Command(24) Status = 11: 2 ==> 0: >While configuring BusLogic Host Adapter at I/O Address 0x330: >INQUIRE DEVICES FAILED - DETACHING >ADDITIONAL FAILURE INFO - Command Invalid >BusLogic_Probe(0x334): Status 0xFF >BusLogic_Probe(0x230): Status 0xFF >BusLogic_Probe(0x234): Status 0xFF >BusLogic_Probe(0x130): Status 0xFF >BusLogic_Probe(0x134): Status 0xFF >scsi : 0 hosts. >scsi : detected total. >Partition check: >VFS: Cannot open root device 08:01 >Kernel panic: VFS: Unable to mount root fs on 08:01
----_--__---_-_-_-__--_-__-__---_-_----_--_-_---_---_---- _/ TANAKA Yoshitomo _// / Suginami-ku Tokyo, Japan _// serow@silkwood.rim.or.jp
| |