Messages in this thread | | | From | Fabio Estevam <> | Date | Tue, 27 Feb 2024 08:22:23 -0300 | Subject | Re: [PATCH net 1/2] net: dsa: mv88e6xxx: fix marvell 6320/21 switch probing |
| |
Hi Steffen,
On Mon, Feb 26, 2024 at 6:15 AM Steffen Bätz <steffen@innosonix.de> wrote: > > As of commit de5c9bf40c45 ("net: phylink: require supported_interfaces to > be filled") > Marvell 88e6320/21 switches fail to be probed: > > ... > mv88e6085 30be0000.ethernet-1:00: phylink: error: empty supported_interfaces > error creating PHYLINK: -22 > ... > > The problem stems from the use of mv88e6185_phylink_get_caps() to get > the device capabilities. Create a new dedicated phylink_get_caps for the > 6320 and 6321 to properly support their set of capabilities. > > Fixes: de5c9bf40c45 ("net: phylink: require supported_interfaces to be filled") > Signed-off-by: Steffen Bätz <steffen@innosonix.de>
Thanks for the fix.
Reviewed-by: Fabio Estevam <festevam@gmail.com>
| |