Messages in this thread | | | Date | Wed, 21 Feb 2024 21:50:26 +0100 | From | Frederic Weisbecker <> | Subject | Re: [PATCH v11 13/20] timers: Add get next timer interrupt functionality for remote CPUs |
| |
Le Wed, Feb 21, 2024 at 10:05:41AM +0100, Anna-Maria Behnsen a écrit : > To prepare for the conversion of the NOHZ timer placement to a pull at > expiry time model it's required to have functionality available getting the > next timer interrupt on a remote CPU. > > Locking of the timer bases and getting the information for the next timer > interrupt functionality is split into separate functions. This is required > to be compliant with lock ordering when the new model is in place. > > Signed-off-by: Anna-Maria Behnsen <anna-maria@linutronix.de>
Reviewed-by: Frederic Weisbecker <frederic@kernel.org>
| |