| Date | Sat, 30 Sep 2023 16:33:18 +0100 | From | Jonathan Cameron <> | Subject | Re: [PATCH v3 23/27] staging: iio: resolver: ad2s1210: convert DOS overrange threshold to event attr |
| |
On Fri, 29 Sep 2023 12:23:28 -0500 David Lechner <dlechner@baylibre.com> wrote:
> From: David Lechner <david@lechnology.com> > > From: David Lechner <dlechner@baylibre.com> > > The AD2S1210 has a programmable threshold for the degradation of signal > (DOS) overrange fault. This fault is triggered when either the sine or > cosine input rises the threshold voltage.
rises above the threshold voltage.
> > This patch converts the custom device DOS overrange threshold attribute > to an event rising edge threshold attribute on the monitor signal > channel. > > The attribute now uses millivolts instead of the raw register value in > accordance with the IIO ABI. > > Emitting the event will be implemented in a later patch. > > Signed-off-by: David Lechner <dlechner@baylibre.com>
|