lkml.org 
[lkml]   [2023]   [Sep]   [30]   [last100]   RSS Feed
Views: [wrap][no wrap]   [headers]  [forward] 
 
Messages in this thread
/
Date
From
SubjectRe: [PATCH v3 23/27] staging: iio: resolver: ad2s1210: convert DOS overrange threshold to event attr
On Fri, 29 Sep 2023 12:23:28 -0500
David Lechner <dlechner@baylibre.com> wrote:

> From: David Lechner <david@lechnology.com>
>
> From: David Lechner <dlechner@baylibre.com>
>
> The AD2S1210 has a programmable threshold for the degradation of signal
> (DOS) overrange fault. This fault is triggered when either the sine or
> cosine input rises the threshold voltage.

rises above the threshold voltage.

>
> This patch converts the custom device DOS overrange threshold attribute
> to an event rising edge threshold attribute on the monitor signal
> channel.
>
> The attribute now uses millivolts instead of the raw register value in
> accordance with the IIO ABI.
>
> Emitting the event will be implemented in a later patch.
>
> Signed-off-by: David Lechner <dlechner@baylibre.com>

\
 
 \ /
  Last update: 2023-09-30 17:34    [W:0.644 / U:1.196 seconds]