Messages in this thread | | | From | cong yang <> | Date | Tue, 4 Jul 2023 19:14:12 +0800 | Subject | Re: [PATCH v3 0/4] Fix up the boe-tv101wum-nl6 panel driver |
| |
Hi,
On Tue, Jul 4, 2023 at 6:16 PM Linus Walleij <linus.walleij@linaro.org> wrote: > > On Tue, Jul 4, 2023 at 12:04 PM cong yang > <yangcong5@huaqin.corp-partner.google.com> wrote: > > On Mon, Jul 3, 2023 at 9:21 PM Linus Walleij <linus.walleij@linaro.org> wrote: > > > > I am surprised that contributors from manufacturers do not seem > > > to have datasheets for the display controllers embedded in the > > > panels of their products. Can you take a second look? > > > > Sorry, this panel datasheet is not open source, I can't share this datasheet. > > Perhaps not, but you can use the knowledge in the datasheet to > name the commands and give better structure to the members of > the driver, if you know what commands mean then provide > #define statements to them so sequences become understandable. > See for example patch 4/4.
Patch 4/4 LGTM, from the datasheet 0XFF is EXTC Command Set Enable . Description: Set the register, 1 Parameter = 98h, 2 Parameter = 82h, 3 Parameter = Page value to enable “page command set” available. 00h = Page 0 ,01h = Page 1... 0Eh = Page 14.