Messages in this thread Patch in this message | | | From | Judith Mendez <> | Subject | [RFC PATCH 3/5] dt-binding: can: m_can: Remove required interrupt attributes | Date | Thu, 13 Apr 2023 17:30:49 -0500 |
| |
Remove required attributes for interrupt and interrupt names since some MCANs may not have hardware interrupt routed to A53 Linux.
Signed-off-by: Judith Mendez <jm@ti.com> --- Documentation/devicetree/bindings/net/can/bosch,m_can.yaml | 2 -- 1 file changed, 2 deletions(-)
diff --git a/Documentation/devicetree/bindings/net/can/bosch,m_can.yaml b/Documentation/devicetree/bindings/net/can/bosch,m_can.yaml index 67879aab623b..43f1aa9addc0 100644 --- a/Documentation/devicetree/bindings/net/can/bosch,m_can.yaml +++ b/Documentation/devicetree/bindings/net/can/bosch,m_can.yaml @@ -122,8 +122,6 @@ required: - compatible - reg - reg-names - - interrupts - - interrupt-names - clocks - clock-names - bosch,mram-cfg -- 2.17.1
| |