On Tue, Apr 11, 2023 at 07:42:50AM -0700, Nikunj Kela wrote:
> that's a good suggestion. Any solution you propose shouldn't just limit to > only one parameter. IMO, there should be some way to pass all 6 parameters > since we do have a use case of at least two parameters.
Please elaborate on your use-case.
> The shmem proposal is fine however please also incorporate passing of other > parameters.
You are missing the point here. SMC/HVC is just a doorbell and the main point I made earlier is that there is no need for vendors to try colourful things here if it is not necessary. So no, I don't want any extra bindings or more than one param is that is not needed. I will wait for the reason as requested above.
-- Regards, Sudeep
| |