Messages in this thread | | | From | "Zhang, Rui" <> | Subject | Re: [PATCH 2/5] thermal/core: Reset cooling state during cooling device unregistration | Date | Wed, 29 Mar 2023 06:28:26 +0000 |
| |
On Tue, 2023-03-28 at 19:54 +0200, Rafael J. Wysocki wrote: > > > What do the other cooling device drivers do in general when they > > > get > > > removed? > > > > No cooling device driver has extra handling after cdev > > unregistration. > > However, the question regarding what to do when the driver of a > cooling device in use is being removed is a valid one. > > One possible approach that comes to mind could be to defer the driver > removal until the overheat condition goes away, but anyway it would > be > better to do that in the core IMV.
In this case, we should guarantee that the thermal zone driver is still functional. i.e. it still can get temperature change notifications and update the thermal zone. I doubt if current thermal zone drivers can guarantee this.
Given that this is a rare case, and the current behavior is not perfect but still acceptable, maybe we can leave this low priority for now.