On Thu, Mar 23, 2023 at 01:04:53PM +0100, Pavel Machek wrote:
> Hi!
>
> > From: Andrew Lunn <andrew@lunn.ch>
> >
> > The WAN port of the 370-RD has a Marvell PHY, with one LED on
> > the front panel. List this LED in the device tree.
> >
> > Signed-off-by: Andrew Lunn <andrew@lunn.ch>
> > Signed-off-by: Christian Marangi <ansuelsmth@gmail.com>
>
> > @@ -135,6 +136,19 @@ &mdio {
> > pinctrl-names = "default";
> > phy0: ethernet-phy@0 {
> > reg = <0>;
> > + leds {
> > + #address-cells = <1>;
> > + #size-cells = <0>;
> > +
> > + led@0 {
> > + reg = <0>;
> > + label = "WAN";
> > + color = <LED_COLOR_ID_WHITE>;
> > + function = LED_FUNCTION_LAN;
> > + function-enumerator = <1>;
> > + linux,default-trigger = "netdev";
> > + };
> > + };
> > };
> >
>
> How will this end up looking in sysfs?

Hi Pavel

It is just a plain boring LED, so it will look like all other LEDs.
There is nothing special here.

> Should documentation be added to Documentation/leds/leds-blinkm.rst
> ?

This has nothing to do with blinkm, which appears to be an i2c LED
driver.

Andrew

\
 
 \ /