Messages in this thread | | | Date | Mon, 20 Mar 2023 17:32:56 +0100 | From | Simon Horman <> | Subject | Re: [PATCH net v2 1/2] smsc911x: only update stats when interface is up |
| |
On Mon, Mar 20, 2023 at 10:20:40AM +0100, Wolfram Sang wrote: > Otherwise the clocks are not enabled and reading registers will BUG. > > Fixes: 1e30b8d755b8 ("net: smsc911x: Make Runtime PM handling more fine-grained") > Suggested-by: Geert Uytterhoeven <geert+renesas@glider.be> > Signed-off-by: Wolfram Sang <wsa+renesas@sang-engineering.com>
Reviewed-by: Simon Horman <simon.horman@corigine.com>
| |