On Mon, Sep 12, 2022 at 10:59:43AM +0200, Camel Guo wrote:
> Previously the duty cycle was divided equally into h_scl_l, t_scl_h.
> This makes the low period of the SCL clock in Fast Mode is only 1.25us
> which is way lower than the minimal value (1.3) specified in i2c
> specification. In order to make sure t_scl_l, t_scl_h always fullfill
> i2c specification, this commit calculates t_scl_l using this formula:
>
> t_scl_l = clk_cycle *
> ((t_low_min + (scl_clock - t_low_min - t_high_min) / 2) / scl_clock)
>
> where:
> t_low_min is the minimal value of low period of the SCL clock in us;
> t_high_min is the minimal value of high period of the SCL clock in us;
> scl_clock is converted from SCL clock frequency into us.
>
> Signed-off-by: Camel Guo <camel.guo@axis.com>

Applied to for-next, thanks!